An A2-70 stainless steel Nylock nut is a 304 stainless hex nut with a nylon insert that grips the bolt thread to resist vibration loosening, rated to ISO 3506 class A2-70 (700 MPa). The nylon collar is what separates it from a plain nut, but it also sets hard limits on temperature and reuse that many buyers overlook. This guide explains how the insert locks, compares Nylock against all-metal lock nuts, and gives the DIN 985 selection path you need to specify correctly.

An A2-70 stainless steel Nylock nut uses an undersized nylon collar to grip the bolt thread, creating prevailing torque that holds the joint tight under vibration without a lock washer. The nylon insert limits service to roughly -40 °C to +120 °C and to a few reuses before grip fades, whereas an all-metal lock nut survives heat and more cycles. Specify it by DIN 985 or ISO 7040 dimensions and ISO 3506 class A2-70, stepping up to A4 (316) where chlorides or marine exposure are present.

Quick Takeaways

  • Nylock = nylon insert lock nut; the undersized nylon collar creates prevailing torque that resists vibration.
  • A2-70 means 304 (A2) stainless at 700 MPa minimum tensile strength.
  • The nylon insert works from roughly -40 °C to +120 °C; above that it softens and loses grip.
  • Nylock nuts can be reused a few times, but grip fades as the nylon wears; all-metal lock nuts tolerate more cycles.
  • Specify dimensions by DIN 985 or ISO 7040; use A4 (316) for marine and chloride service.
  • Install the nut insert-side first; the bolt must fully engage the nylon to lock correctly.

What Is an A2-70 Stainless Steel Nylock Nut?

A Nylock nut is a locknut — a nut) with a self-locking element — in which a nylon collar is fitted into the top of the nut. The brand name "Nylock" has become generic shorthand for any nylon insert lock nut, and the parts themselves are standardized under DIN 985 and ISO 7040. The two-part name of this article describes the whole part: A2-70 names the material and strength, "stainless steel" names the corrosion behavior, and "Nylock" names the locking mechanism.

Two related products are worth separating. A nylon insert nut carries a full nylon collar at the top of the nut, while a thread-patch nut has nylon bonded directly into a portion of the thread. The insert type — the subject here — provides more locking engagement and is the standard under DIN 985 and ISO 7040. The patch type is a lighter-duty alternative used where a full collar would not fit.

stainless-steel-nylock-nut.jpg

How the Nylon Insert Locks: Prevailing Torque Explained

The nylon insert is the entire point of the fastener. The collar is molded slightly under-sized relative to the bolt thread, so when a bolt is wound through, the metal threads engage normally first and then the bolt enters the nylon. The nylon deforms elastically and grips the thread, generating prevailing torque — friction that resists rotation independently of the clamping load. Because that friction remains even if clamp load relaxes, the nut stays tight under vibration where a plain nut would back off.

Prevailing torque is measurable, not a marketing claim. ISO 2320 defines the test: the nut must show a specified breakaway (first-on) torque and a specified prevailing torque on first removal, then meet a minimum on the fifth removal cycle. This is what separates a genuine lock nut from a nut that merely has a nylon ring glued in. When a supplier cannot quote ISO 2320 performance for its Nylock nuts, the locking function is unverified.

loosening-test-for-nylock-nuts.jpg

A2-70: What the Grade Means

A2-70 is an ISO 3506 property class written in two parts. A2 designates the material family — 304 austenitic stainless steel, the same material called 18-8 or EN 1.4301 — and 70 means a 700 MPa minimum tensile strength. The A2 (304) choice is the workhorse for general corrosion resistance; where chlorides, seawater, or coastal salt are present, the same nut in A4 (316) is the correct step-up.

On strength, A2-70 and A4-70 are equivalent — 316 is not inherently stronger than 304, only more corrosion-resistant. The choice between A2 and A4 is therefore about chlorides, not load, which is why a marine specification calls for A4-70 rather than A2-70 at the same strength.

Nylock Nut vs All-Metal Lock Nut: Head-to-Head Comparison

The locking decision is really a choice between two mechanisms: a nylon insert, or a deformed metal thread. AOZHAN supplies both families of stainless steel nuts, and the table below compares them across the dimensions that decide the call.

Property

Nylock (Nylon Insert)

All-Metal Lock Nut

Locking mechanism

Nylon collar grips thread

Deformed / distorted thread

Temperature limit

~ -40 °C to +120 °C

Higher, up to several hundred °C

Reusability

A few cycles, grip fades

More cycles

Corrosion resistance

Nylon + A2/A4 metal

Metal only, same grades

Damage to mating thread

Minimal

Slightly more aggressive

Typical use

General vibration, automotive

Hot, high-cycle, harsh duty

For a closer look at how the two stack up in practice, see AOZHAN's applications of stainless steel lock nuts.

The choice reduces to two questions: how hot, and how often. If the joint stays below about 120 °C and is assembled once or a few times, the Nylock is usually the simpler, gentler choice. If the joint runs hot or is disassembled repeatedly, an all-metal lock nut is the more robust option. There is no universal "better" — the two mechanisms serve different duty cycles, and the wrong one fails in a predictable way.

Temperature Limits and Reusability: What Nylon Can't Do

The nylon insert is both the Nylock's strength and its constraint. Standard nylon (polyamide 6 or 6/6) retains elasticity from roughly -40 °C to +120 °C in service. Above about 120 °C the nylon softens and the prevailing-torque grip on the thread drops off; sustained service above roughly 130–140 °C permanently deforms the insert and destroys the locking function. Special high-temperature inserts built from engineering polymers can push the limit toward 180 °C, but even those fall far short of an all-metal lock nut.

Reusability follows the same logic. Nylon has good memory, so a Nylock nut can be removed and re-torqued a few times, but each cycle wears the insert and progressively reduces grip. All-metal lock nuts tolerate more removal cycles before their locking torque falls below specification. For safety-critical or hot joints, the safe practice is a fresh lock nut per assembly, and any reuse should be followed by a prevailing-torque check rather than assumed. AOZHAN's DIN 985 nylon nut vibration resistance note covers these limits in more detail.

Testing after reuse is cheap insurance. A reused Nylock nut should still show measurable prevailing torque when threaded onto the bolt; if the nut can be run on by hand nearly to the seated position without resistance, the insert is worn out. For any joint whose failure is costly or unsafe, the economical rule is to treat the Nylock as single-use rather than gamble on a worn insert.

Standards and Sizes: DIN 985, ISO 7040, ISO 10511

Three references cover the common Nylock nut. DIN 985 is the classic European standard for nylon insert hex nuts, and ISO 7040 is the international prevailing-torque type 1 equivalent; ISO 10511 covers the thin (jam) version.

Standard

Scope

What it governs

DIN 985 / ISO 7040

Nylon insert hex lock nut

Dimensions, prevailing torque

ISO 10511

Thin nylon insert nut

Reduced-height version

DIN 982

Heavy nylon insert nut

Higher-thickness variant

ISO 3506-2

Stainless nuts

Property class A2-70

Sizes run from M3 to M64 and larger, across coarse and fine pitch. AOZHAN's nylon locknut size and specification guide walks through the full dimensional range so the insert thickness, width across flats, and thread pitch are all specified consistently.

Two sizing details trip up first-time buyers. First, thread pitch: a Nylock nut must match the bolt's coarse or fine pitch exactly, because the nylon collar grips the thread form and the wrong pitch will not lock. Second, height: DIN 985 is the standard height, DIN 982 is the heavy (taller) version, and ISO 10511 is the thin version — a thin jam nut used where a full-height nut belongs changes the engagement length and the joint's load capacity.

How A2-70 Nylock Nuts Are Made (Factory Perspective)

The part is produced in two stages that must both be controlled: the metal nut and the nylon insert. At AOZHAN, 304 stainless bar is cut and cold-formed into the hex blank, the internal thread is tapped, and the nut is then pressed with the nylon collar, which is seated into a counterbore at the top of the nut and retained by its interference with the thread. The finished part is checked for dimensions, thread fit, and prevailing torque against the standard before release. This sequence, documented in AOZHAN's production and inspection workflow, is what keeps the insert seated and the locking torque consistent across a batch.

The interference between the nylon collar and the thread is what keeps the insert in place, so the counterbore depth and the collar dimensions must both be held within tolerance. AOZHAN verifies that the insert is seated flush and that the prevailing torque meets the standard on a sampling basis, because an insert that sits proud or a counterbore that is too shallow will loosen the collar after only a few cycles.

Where A2-70 Nylock Nuts Are Used: Automotive, Machinery, Vibration

Nylock nuts earn their place wherever vibration would loosen a plain nut and a lock washer is not reliable enough. Automotive assembly is the classic home — engine accessories, chassis brackets, and trim hardware that must survive years of road vibration. General machinery, pumps, conveyors, and appliances use the same principle to keep fasteners seated without periodic re-tightening. In each case the nylon insert provides the locking action while the A2-70 stainless body provides the corrosion resistance, giving one part that solves both problems.

AOZHAN has supplied A2-70 stainless steel Nylock nuts for automotive and machinery applications where vibration resistance and corrosion resistance were both written into the drawing. Representative installations appear in AOZHAN's customer cases, and the automotive-side logic is covered in AOZHAN's nylon lock nut automotive advantages note.

In appliance and equipment manufacturing, the Nylock's value is partly about assembly consistency. Because the locking element is integral to the nut, the assembler cannot forget a lock washer or misplace it, which removes a variable from the line. That reliability, combined with the corrosion resistance of the A2-70 stainless body, is why the same part number shows up across washing machines, pumps, and light vehicle chassis.

Industrial-nylon-insert-lock-nuts.jpg

How to Choose the Right A2-70 Stainless Nylock Nut

Selection should follow the environment first, the temperature second, and the specification third. Working in that order prevents the common mistake of specifying a Nylock for a hot joint where the nylon will fail.

A 4-Step Selection Path

  1. Define the environment. Use A2 (304) for general and indoor service; step up to A4 (316) where chlorides, seawater, or coastal salt are present.
  2. Check the temperature. Confirm the joint stays below about 120 °C. For hotter service, choose an all-metal lock nut or a high-temperature insert.
  3. Confirm reuse expectations. Use a Nylock where the joint is assembled once or a few times; choose all-metal for high-cycle or frequent-disassembly service.
  4. State the standards. Specify DIN 985 or ISO 7040 dimensions and ISO 3506 class A2-70, with the thread pitch and width across flats.

Pre-Order Inspection Checklist

  • Material and class stated as A2-70 (304) on the order, or A4 (316) for marine service
  • Standard named (DIN 985 / ISO 7040) with thread pitch and size
  • Insert type confirmed (nylon) and temperature rating noted
  • Prevailing torque requirement referenced (ISO 2320)
  • Passivation or surface finish specified where required
  • Material test certificate requested for regulated or load-critical applications

For a quotation or to confirm a class and size against your project spec, contact AOZHAN's engineering team.

Installation direction deserves a final note. The Nylock nut must be threaded on with the nylon insert trailing, so the bolt passes through the metal threads first and only then enters the nylon. Fitted the wrong way, the insert is crushed before the thread engages, and the locking function is compromised even though the nut looks seated. For controlled-torque joints, remember the insert adds prevailing torque on top of the clamp torque, so tightening should be to the total value the specification defines.

FAQ

Can Nylock nuts be reused?

Yes, but only a few times. Each removal wears the nylon insert and reduces its grip. For safety-critical or hot joints, install a fresh nut and verify prevailing torque rather than assuming reuse is safe.

What does A2-70 mean?

A2 designates the 304 stainless family, and 70 means a 700 MPa minimum tensile strength. A4 is the 316 family, and A4-80 is the higher-strength, chloride-resistant class.

What is the difference between a Nylock and an all-metal lock nut?

A Nylock locks with a nylon insert that grips the thread, while an all-metal lock nut locks with a deformed thread. All-metal nuts tolerate higher temperatures and more reuse cycles but are slightly more aggressive on the mating thread.

How hot can a Nylock nut get?

Standard nylon inserts retain grip from roughly -40 °C to +120 °C. Above about 120 °C the nylon softens and loses grip, and sustained heat above 130–140 °C damages the insert permanently. Use all-metal or high-temperature inserts for hotter duty.

Should I choose A2 or A4 for a Nylock nut?

Choose A2 (304) for general, indoor, and mild outdoor service. Choose A4 (316) where chlorides, seawater, or coastal salt are present, because A4's molybdenum resists the pitting that would attack A2.

Which way does a Nylock nut go on?

The nylon insert goes on last — the bolt threads through the metal threads first and then enters the nylon collar. Fitting it insert-side first ensures the bolt fully engages the nylon and locks correctly.